Customization: | Available |
---|---|
Warranty: | 1 Year |
Type: | Strength Testing Machine |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1 | Diameter of sample sheet: | ≤ 200mm |
2 | Vacuum degree of vacuum pump: | 0.092-0.098MPa |
3 | Drying temperature: | ≤105°C |
4 | Drying time (30-80g/m2 quantitative): | 3-6 minutes |
5 | Heating power: | 1.5KW×2; voltage: 220V |
6 | XMT616 intelligent PID temperature controller × 2 | |
Working power supply: | AC 85-260V (50HZ/60HZ) | |
Thermal resistance: | PT100 Operation environment: 0-±50oC: ≤85% RH | |
Contact capacity: | AC 250V/3A Measurement accuracy: 0.2% F.S | |
7 | DHC9J-L time totalizer | |
E2ROM is used to store data; the data can be stored for ten years and are displayed with a five-digit LED digital display. | ||
The scope of the time totalizer is between 1s-9999.9h. | ||
ower supply voltage: | AC 100V-240V | |
Power consumption: | ≤3.5VA Time precision: ≤0.1% | |
8 | Power of vacuum pump motor: | 2.2KW Voltage: 380V |
9 | Power of jet self-priming stainless steel pump motor: | 370W Voltage: 380V |
10 | Inflation valve for electromagnetic vacuum belt: | current 0.048A Voltage 220V |
11 | Vacuum electromagnetic valve: | ×2 Voltage: 220V |
12 | Electromagnetic valve for water drainage: | voltage 220V |
13 | Mesa Material: | stainless steel (304L) |
14 | Equipped with four standard floating press rollers (304L) with a weight of 13.3Kg each. | |
15 | Coupled with a spraying and washing device. | |
16 | Outline dimensions: | 1800mm×710mm×1300mm |